I found the issue 

You have to connect to the systemBus not to the sessionBus!

if (QDBusConnection::systemBus().connect("de.pengutronix.rauc",                                         //Service
                                 "/",                               //Path
                                 "org.freedesktop.DBus.Properties", //Interface
                                 "PropertiesChanged",
                                 this,
                                 SLOT(propertyChanged(const QString& ,
                                                      const QMap<QString, QVariant>& ,
                                                      const QStringList& )))) {

        qDebug() << "PropertiesChanged signal connected successfully to slot";
        } else {
        qDebug() << "PropertiesChanged signal connection was not successful";
        }

Now I my function propertyChanged is called every time the property changes.

If you use 

Von: RAUC <rauc-bounces@pengutronix.de> im Auftrag von Stahl, Michael <mstahl@moba.de>
Gesendet: Dienstag, 3. August 2021 10:27
An: Eugen.Wiens@JUMO.net <Eugen.Wiens@JUMO.net>
Cc: RAUC <rauc-bounces@pengutronix.de>; RAUC@pengutronix.de <RAUC@pengutronix.de>
Betreff: Re: [RAUC] Antwort: Re: Antwort: Re: Antwort: Re: Antwort: D-Bus control Qt
 
Hi Euen,

I know but I am stucking. I am polling the propery "Operation". Just when it changes from "idle" to "installing" I subscribe the PropertiesChanged signal but without success. I tried several connect strings but all without success. 


if (QDBusConnection::sessionBus().connect("de.pengutronix.rauc",
                                 "/",
                                 "org.freedesktop.DBus.Properties",
                                 "PropertiesChanged",
                                 this,
                                 SLOT(propertyChanged(const QString& ,
                                                      const QMap<QString, QVariant>& ,
                                                      const QStringList& )))) 
{
    qDebug() << "PropertiesChanged signal connected successfully to slot";
} else {
    qDebug() << "PropertiesChanged signal connection was not successful";
}

Please can you tell me how to subcribe the PropertiesChanged signal?


Von: Eugen.Wiens@JUMO.net <Eugen.Wiens@JUMO.net>
Gesendet: Dienstag, 3. August 2021 08:27
An: Stahl, Michael <mstahl@moba.de>
Cc: RAUC@pengutronix.de <RAUC@pengutronix.de>; RAUC <rauc-bounces@pengutronix.de>
Betreff: Antwort: Re: [RAUC] Antwort: Re: Antwort: Re: Antwort: D-Bus control Qt
 
Hi Michael,

you can connect to a property change on dbus level. That is the way we do it.


"RAUC" <rauc-bounces@pengutronix.de> schrieb am 03.08.2021 08:21:32:

> Von: "Stahl, Michael" <mstahl@moba.de>

> An: "Eugen.Wiens@JUMO.net" <Eugen.Wiens@JUMO.net>
> Kopie: "RAUC" <rauc-bounces@pengutronix.de>, "RAUC@pengutronix.de"
> <RAUC@pengutronix.de>

> Datum: 03.08.2021 08:21
> Betreff: Re: [RAUC] Antwort: Re:  Antwort: Re:  Antwort:  D-Bus control Qt
> Gesendet von: "RAUC" <rauc-bounces@pengutronix.de>
>
> Hi Eugen,

>
> thanks again. I implemented the signal and now I get the signal that
> the update is finished.

> But thats the only signal that rauc is provided, isn't it? To get
> the progress I have to poll the property, or are there general
> signals on the dbus that I can connect to?

>
> Do you read the property "Progress" like

> QDBusInterface iface( "de.pengutronix.rauc",
>                  "/",
>                  "de.pengutronix.rauc.Installer",
>                  QDBusConnection::systemBus() );
> QVariant property = iface.property("Progress");
> MyProgress parameterProgress;
> property.value<QDBusArgument>() >> parameterProgress;
>
> or did you use another possibility?

> If I use the above I get a message five times and the marshaled data (
> m_Progress, m_Message, ..) are always empty.

> QDBusArgument: read from a write-only object

>
> Von: Eugen.Wiens@JUMO.net <Eugen.Wiens@JUMO.net>
> Gesendet: Montag, 2. August 2021 16:53
> An: Stahl, Michael <mstahl@moba.de>
> Cc: RAUC@pengutronix.de <RAUC@pengutronix.de>; RAUC <rauc-
> bounces@pengutronix.de>
> Betreff: Antwort: Re: [RAUC] Antwort: Re: Antwort: D-Bus control Qt

>  
> Hi Michael,
>
> "RAUC" <rauc-bounces@pengutronix.de> schrieb am 02.08.2021 16:29:18:
>
> > Von: "Stahl, Michael" <mstahl@moba.de>
> > An: "Eugen.Wiens@JUMO.net" <Eugen.Wiens@JUMO.net>
> > Kopie: RAUC <rauc-bounces@pengutronix.de>, "RAUC@pengutronix.de"
> > <RAUC@pengutronix.de>
> > Datum: 02.08.2021 16:29
> > Betreff: Re: [RAUC] Antwort: Re:  Antwort:  D-Bus control Qt
> > Gesendet von: "RAUC" <rauc-bounces@pengutronix.de>
> >
> > Okay, thanks a lot.
> >
> > A last question. Is it correct that I have to poll the "Progress"
> > property or is there any signal system where I can subcribe to get a
> > notification at every change of progress status?
>
> We are using a dbus signal. You can connect to it with Qt.
>
> Best regards,
> Eugen

> Diese E-Mail kann vertrauliche und/oder rechtlich gesch?tzte
> Informationen beinhalten und ist ausschlie?lich f?r die im Verteiler
> genannten Personen bestimmt. Das unerlaubte Kopieren sowie die
> unbefugte Weitergabe dieser Mail sind nicht gestattet. Bitte
> benachrichtigen Sie uns gegebenenfalls telefonisch oder mit Antwort-
> Mail, falls Sie nicht der richtige Adressat dieser E-Mail sind.
> Bitte l?schen Sie diese Nachricht und alle Anh?nge dazu unverz?
> glich. Falls nicht ausdr?cklich vermerkt, ist diese E-Mail keine
> rechtlich bindende Vereinbarung.
>
> Kommanditgesellschaft: JUMO GmbH & Co. KG, Sitz: 36039 Fulda,
> Amtsgericht Fulda HRA 302, Pers?nlich haftende Gesellschafterin: M.
> K. JUCHHEIM GmbH, Sitz: 36039 Fulda, Amtsgericht Fulda HRB 17,
> Gesch?ftsf?hrer: Dipl.-Ing. Bernhard Juchheim, Dipl.-Kfm. Michael
> Juchheim, Dipl.-Ing. Dimitrios Charisiadis
> Ust.-Id.-Nr.: DE 112411234_______________________________________________
> RAUC mailing list

Diese E-Mail kann vertrauliche und/oder rechtlich gesch?tzte Informationen beinhalten und ist ausschlie?lich f?r die im Verteiler genannten Personen bestimmt. Das unerlaubte Kopieren sowie die unbefugte Weitergabe dieser Mail sind nicht gestattet. Bitte benachrichtigen Sie uns gegebenenfalls telefonisch oder mit Antwort-Mail, falls Sie nicht der richtige Adressat dieser E-Mail sind. Bitte l?schen Sie diese Nachricht und alle Anh?nge dazu unverz?glich. Falls nicht ausdr?cklich vermerkt, ist diese E-Mail keine rechtlich bindende Vereinbarung.

Kommanditgesellschaft: JUMO GmbH & Co. KG, Sitz: 36039 Fulda, Amtsgericht Fulda HRA 302, Pers?nlich haftende Gesellschafterin: M. K. JUCHHEIM GmbH, Sitz: 36039 Fulda, Amtsgericht Fulda HRB 17, Gesch?ftsf?hrer: Dipl.-Ing. Bernhard Juchheim, Dipl.-Kfm. Michael Juchheim, Dipl.-Ing. Dimitrios Charisiadis